The Mega-Guard Alarm and Monitoring System (AMS) is
the perfect solution for small vessels. The Mega-Guard AMS
supports both manned and unmanned machinery space
applications.
The Alarm Panel is the main component of the AMS and this
panel contains 16 digital inputs with a text window and LED
alarm indication. This stand-alone panel communicates with
other Alarm Panels and with the Group Alarm Panel on bridge
via a redundant Ethernet network. The Group Alarm Panel
on bridge is physically the same panel as the Alarm Panel.
The basic AMS can be extended with analog inputs by
installing an EAS Operator Panel and one or two 24 channel
Analog Input I/O Modules. The EAS Operator Panel is used
for alarm indication and measured value indication.
The EAS Operator Panel is also equipped with a RS485
serial interface to read values from other equipment.
The Mega-Guard AMS can also be expanded with an
Extension Alarm System for unmanned machinery space
notation (UMS). In this case the EAS Operator Panel is
required for Attended/Unattended selection, on duty selection
and patrol timer functions. An EAS 3 LED Panel is installed in
cabin's and public spaces in order to call the on duty
engineer
in case an alarm is coming.
Features
The Alarm Panel supports 16 potential free alarm contacts
(digital inputs) and 2 alarm inhibition inputs. Alarm Panels
are interconnected by a redundant Ethernet network. Ring
Ethernet wiring is fully supported by the Mega-Guard AMS.
The Alarm Panel is equipped with an Alarm LED for each
input channel and an Acknowledge and Stop Horn pushbutton.
A text sheet with channel description for each channel is
inserted from the top. Background illumination will shine
through this text sheet for night visibility of the channel
descriptions. Background dimming level can be adjusted in
normal operation mode by pressing the Arrow Left and
Arrow Right pushbuttons. The Alarm Panel is equipped with
a 2 line by 16 character display which displays diagnostic
messages during normal operation mode. The display is
also used for programming the Alarm Panel during installation.
The programmed data is stored inside the Panel and can be
saved or loaded via a USB memory stick. A Lamp Test of
the unit can be performed when pressing Ack and Stop Horn
at the same time during normal operation. The Alarm Panel
has standard DIN size 144x144mm for flush panel console
mounting. The rear of the unit is equipped with detachable
terminal strips for field wiring.